2 Way Manifold Valves
Block-and-bleed manifolds for pressure gauges and single-sided instruments.
2 Way Manifold Valves
Block-and-bleed manifolds for pressure gauges and single-sided instruments.
Overview
Block-and-bleed manifolds for pressure gauges and single-sided instruments. This range covers 5 variants: 2M-01, 2M-02, 2M-03, 2M-04, 2M-05. 2M-01 — A 2-way manifold consolidates the isolation, equalisation and venting functions of an instrument hook-up into a single forged body, replacing an assembly of separate valves and fittings. Fewer joints means fewer potential leak paths and a considerably faster installation. A 2-way manifold provides a block valve and a test or drain port, used with gauge and single-sided pressure instruments. Configuration 2M-01 defines the specific port arrangement and mounting pattern; full dimensional drawings are available on request. 2M-02 — A 2-way manifold consolidates the isolation, equalisation and venting functions of an instrument hook-up into a single forged body, replacing an assembly of separate valves and fittings. Fewer joints means fewer potential leak paths and a considerably faster installation. This arrangement suits direct gauge mounting where a single isolation point and a vent are required. Configuration 2M-02 defines the specific port arrangement and mounting pattern; full dimensional drawings are available on request. 2M-03 — A 2-way manifold consolidates the isolation, equalisation and venting functions of an instrument hook-up into a single forged body, replacing an assembly of separate valves and fittings. Fewer joints means fewer potential leak paths and a considerably faster installation. Configured for remote mounting where the instrument sits away from the process tapping. Configuration 2M-03 defines the specific port arrangement and mounting pattern; full dimensional drawings are available on request. 2M-04 — A 2-way manifold consolidates the isolation, equalisation and venting functions of an instrument hook-up into a single forged body, replacing an assembly of separate valves and fittings. Fewer joints means fewer potential leak paths and a considerably faster installation. Suited to applications requiring an additional calibration connection alongside isolation. Configuration 2M-04 defines the specific port arrangement and mounting pattern; full dimensional drawings are available on request. 2M-05 — A 2-way manifold consolidates the isolation, equalisation and venting functions of an instrument hook-up into a single forged body, replacing an assembly of separate valves and fittings. Fewer joints means fewer potential leak paths and a considerably faster installation. A compact variant for installations with restricted clearance around the instrument. Configuration 2M-05 defines the specific port arrangement and mounting pattern; full dimensional drawings are available on request.
Advantages
- Superior build quality with premium materials.
- High resistance to extreme temperatures and pressures.
- Seamless integration with existing automation systems.
- Low maintenance requirements resulting in lower TCO.